How We Estimate HVAC Costs
Every number on New HVAC Cost comes from a public source, and every price is converted to Nov 2025–Oct 2026 prices. This page explains where the data comes from, how we turn it into the ranges you see and what the estimates cannot tell you.
How to read our price ranges
Most prices on this site are shown as a range from a basic price to a typical price.
- Basic price is a federal estimate of the installed cost, converted to current prices.
- Typical price multiplies the federal estimate by one factor, taken from a multi-state database of home retrofit projects compiled by Lawrence Berkeley National Laboratory (LBNL). For air conditioners and heat pumps, the factor is set at one point, a 3 ton air conditioner, and every other size and setup is scaled by the same ratio. Gas furnaces have their own factor (see below).
The LBNL median is higher than the federal estimate. The two sources were built in different ways, so rather than pick one we show both ends.
Bringing old prices up to date
Our sources report prices in the dollars of their own year (from 2015 to 2022). We convert them with the U.S. Bureau of Labor Statistics producer price index for plumbing and HVAC contractors, nonresidential building work (series PCU23822X23822X), using the average of the 12 months Nov 2025–Oct 2026. The index covers nonresidential work, so for home jobs it is an approximation. The most recent months are preliminary and may be revised by BLS. We bring prices up to date with the latest index at least once a year. Data retrieved from BLS on November 25, 2026. BLS.gov cannot vouch for the data or analyses derived from these data after the data have been retrieved from BLS.gov.
Central air conditioners and heat pumps
- Basic price. From the Department of Energy's technical support document for the central air conditioner and heat pump standards (docket EERE-2014-BT-STD-0048, December 2016), chapter 8, which gives installed costs for split systems at 2, 3 and 5 tons in 2015 dollars. We use two setups: a new outdoor unit with a matching indoor coil (the furnace stays), and a new outdoor unit with a new air handler.
- Typical price. One factor for all air conditioner and heat pump sizes: the median cost of 71 central air conditioner projects in Less et al., The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes (Lawrence Berkeley National Laboratory, 2021), divided by DOE's 3 ton price for a new outdoor unit and coil at SEER 14, converted to the same year's dollars. The LBNL database pools projects from 15 states and 12 energy programs; it is not a national random sample, and LBNL adjusted its costs to 2019 national-average values.
- Sizes DOE did not price. 2.5 tons is the midpoint of the 2 and 3 ton prices; 3.5 tons is a quarter of the way from 3 to 5 tons; 4 tons is the midpoint of 3 and 5 tons. These are less certain than the sizes DOE priced directly.
- North and South. Federal rules require more efficient central air conditioners in the Southeast and Southwest (10 CFR 430.32(c)(6)). DOE's cost tables are organized by efficiency on the older SEER rating scale. For northern states we use DOE's price at SEER 14. For southern states we use its price at SEER 15 for 2 to 3.5 tons and at SEER 14.5 for 4 and 5 tons, because the southern minimum is lower for units with a certified capacity of 45,000 BTU per hour and up (we place sizes by their nominal capacity). This is our choice of how to reflect the rule, not a DOE regional price. Arizona, California, Nevada and New Mexico also have a minimum EER2 rating that our southern prices do not reflect, so prices there may be higher. Heat pumps have one national price, at SEER 15.
- Which states count as southern. Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, Puerto Rico, South Carolina, Tennessee, Texas, Virginia, District of Columbia, U.S. Territories; Arizona, California, Nevada, New Mexico.
Gas furnaces
Basic prices come from the Department of Energy's 2023 final rule for consumer furnaces (Federal Register document 2023-25514), in 2022 dollars, for a 95% efficient gas furnace, the minimum that rule sets for indoor (non-weatherized) gas furnaces and manufactured home gas furnaces made on or after December 18, 2028. In February 2026, the American Gas Association and two other groups petitioned DOE to change that date, and DOE asked for comments in April; as of November 25, 2026, the Federal Register showed no decision. A separate typical-price factor comes from the LBNL study's median furnace price. The price for an 80% furnace is an estimate: the 95% price minus the range of price differences DOE reports between the two, as we read the rule's text. DOE's extra installation items, such as new venting, are listed for information but not added, because DOE's average prices appear to already include them for the share of homes that need them.
Whole-system prices
For central AC with a gas furnace, the home page calculator adds our central AC price (new outdoor unit and indoor coil) to our high-efficiency gas furnace price. We do not subtract anything for doing both jobs at once, because we found no public data on whether there is a saving. The heat pump option and the central AC with air handler option use those systems' own prices. None of the three includes ductwork, and sizes DOE did not price are estimated as described above.
Ductwork
Duct replacement and duct sealing prices are the LBNL study's medians, converted from 2019 dollars. There is only one source here, so these prices are not split into basic and typical. Our per-square-foot rate is $2.93.
Mini splits
Mini split prices come from New York State Energy Research and Development Authority (NYSERDA) open data on data.ny.gov: ductless heat pump projects in detached single-family homes approved from 2017 through 2019. Each project is converted from its approval year, then we report the median and the middle half of prices by number of indoor units. These are prices before state incentives, and they come from one state only.
Sizing rules
- Cooling-led sizing. Floor area divided by about 682.6 sq ft per ton, rounded to the nearest standard size (ties go up). The ratio comes from two median costs for central air conditioners in the LBNL study, about $2,000 per ton and $2.93 per square foot in 2019 dollars (not the same figure as our current duct rate). It is a rough rule for typical homes, not a load calculation, and we only apply it from 600 to 3,500 sq ft. For heat pumps in mild climates we use the same ratio; LBNL's heat pump projects imply a somewhat smaller area per ton, so the ton figure for a heat pump may come out a little low.
- Cold-climate sizing. The median system size of whole-home heat pump projects approved in 2019 in New York State, by floor-area band. A project's system size adds up the cooling capacity of its outdoor units, read from their model numbers, at 12,000 BTU per hour per ton. These systems were likely sized with heating in mind and may run large for milder climates. Bands with fewer than 20 homes are marked as small samples.
- Room BTU. The ENERGY STAR room air conditioner sizing chart, which assumes 8-foot ceilings, with its four adjustments: 10% less for a heavily shaded room, 10% more for a very sunny one, 600 BTU per person beyond two, and 4,000 BTU for a kitchen. The chart doesn't say which order to apply them in; we apply the percentages first. Mini split sizing uses the same chart, one room at a time.
- Units. One ton of cooling is 12,000 BTU per hour (NIST Special Publication 811). Airflow conversions use 60 minutes per hour and 144 square inches per square foot.
Other facts on the site
Equipment lifespans come from the same DOE documents. Facts about refrigerants come from the Environmental Protection Agency, tax credits from the Internal Revenue Service, and duct leakage from ENERGY STAR. Each page names its sources in a box at the bottom.
What these estimates cannot tell you
- They are national or single-state figures. Local labor costs, permits and access can move a real quote well outside our range.
- The underlying data is several years old and has been brought forward with a price index, which tracks prices for plumbing and HVAC contractors' nonresidential work, not any one product.
- Floor-area sizing ignores insulation, windows, climate and layout. Only a Manual J load calculation can size a system for your home.
How we check the numbers
Every figure is kept in one record with its source, the table or page it came from and how it was calculated. Most numbers are filled into the pages automatically from that record; the few typed by hand are checked against it one by one. New data is copied or recalculated from the original source a second time, separately from the first pass, before it goes live, and the calculators are tested against a set of worked answers whenever the site is rebuilt. If you find an error, please contact us.
Sources
- U.S. Department of Energy. Technical support document: energy conservation standards for residential central air conditioners and heat pumps, docket EERE-2014-BT-STD-0048, document EERE-2014-BT-STD-0048-0098, December 2016.
- U.S. Department of Energy. Energy conservation standards for consumer furnaces, final rule, Federal Register document 2023-25514.
- Less, B., Walker, I., et al. The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes. Lawrence Berkeley National Laboratory, 2021. We cite figures from this report; we do not reproduce its charts, and LBNL does not endorse this site.
- New York State Energy Research and Development Authority, open data on data.ny.gov (datasets dpke-svni and 6wkt-wpbr), retrieved November 25, 2026. We publish only summary figures, never individual project records.
- U.S. Bureau of Labor Statistics, producer price index PCU23822X23822X, retrieved November 25, 2026.
- ENERGY STAR, room air conditioner sizing chart. ENERGY STAR is a registered trademark of the U.S. Environmental Protection Agency; we are not affiliated with or endorsed by ENERGY STAR.
- 10 CFR 430.32, energy conservation standards and their compliance dates.
- NIST Special Publication 811, Appendix B.9.